Figure 1: ERW pipe failed in service due to selective corrosion at the seam weld
Potential E0 |
-0.020 V vs open circuit potential |
Potential E1 |
0.020 V vs open circuit potential |
Step height |
0.100 mV |
Scan rate |
0.166 mV/s |
Step time |
0.602 s |
Number of points |
401 |
Table 1: Polarization parameters
Sample |
% C |
% P |
% S |
% Mn |
% Si |
% Cu |
Annealed |
0.2 |
0.03 |
0.031 |
1.16 |
0.06 |
0.054 |
Non- annealed |
0.2 |
0.02 |
0.028 |
0.88 |
0.02 |
0.05 |
API5L2000 |
0.18-0.23 |
0.03 max |
0.031 max. |
1.40 |
- |
- |
Table 2: Chemical analysis results (% W)
Sample/features |
% vol. inclusions |
% vol. ferrite |
% vol. pearlite |
ASTM |
Vickers |
Annealed base metal |
0.45 |
76 |
24 |
10 |
187 |
Annealed ERW seam |
0.61 |
68 |
32 |
11 |
190 |
Non-annealed base metal |
0.62 |
73 |
27 |
8 |
214 |
Non-annealed ERW seam |
0.80 |
62 |
38 |
11.5 |
242 |
Table 3: Quantitative microstructure features of samples
|
Sour solution |
Acid solution |
Zone |
CR [mp/y] |
CR [mp/y] |
Annealed base metal |
23.20 |
36.26 |
Annealed ERW seam |
28.15 |
40.10 |
Non-annealed base metal |
23.90 |
29.45 |
Non-annealed ERW seam |
30.45 |
34.16 |
Table 4: Electrochemical parameters applied in the PR tests
Figure 1: ERW pipe failed in service due to selective corrosion at the seam weld
Figure 2: Diagram of the of the sample section
Figure 3: Princeton EG and G applied research digital potentiostatic. (a) Gases system. (b) Cell used. (c) Computer system
Figure 4: Non-annealed pipe microstructure, etched with 3% Nital [26, 27]. (a) Base metal; (b) Welded area; (c) HAZ
Figure 5: Annealed pipe microstructure, optical microscope [27]. (a) Base metal; (b) Internal surface; (c) ERW seam
Figure 6: Internal surface microstructure of the non-annealed pipe. (a) Before corrosion test; (b) After corrosion test (c) Corrosion product
Figure 7: Sample wall microstructure at the ERW seam after the SPP electrochemical test.
Figure 8: Current trend during 3.3 h SPP electrochemical test, corrosion test solution pH = 3
Figure 9: Current trend during 3.3 h SPP electrochemical test, corrosion test solution pH = 5